Warranty: | 2 Years |
---|---|
Nominal Capacity: | / |
Cycle Life: | / |
MOQ: | 2 |
Transport Package: | Standard |
Specification: | GY5.12-LB Low voltage sub-box A 48V50AH |
Samples: |
discussion
|
---|
Customization: |
---|
Suppliers with verified business licenses
Energy Storage Applications Scenario
Power generation:
1.Peak shaving FM
2.Smooth wind output power
3.Track plan output
4.Local consumption, reducing abandoned wind and solar
5.Active power control and reactive power compensation
Transmission:
1.Slow investment in transmission equipment
2.Improve power quality and system reliability
3.Maintain the voltage stability of the transmission grid
Distribution:
1.Alleviate peak load demand and slow network upgrade and expansion
2.Respond to fault conditions and ensure stable power supply power side
Power side:
1.Auxiliary distributed power access
2.Deal with peak load needs, peak arbitrage
3.Adjust and improve power quality, act as UPS/EPS power supply
Item Number | GY5.13-LB | GY10.24-LB | GY15.36-LB | GY20.48-LB | GY25.6-LB |
Compatible_x0001_with inverter | Deye, Goodwe, Growatt, Aiswei, Ginlong, Megarevo | ||||
Cell type | LFP(LiFePo4) | ||||
Connection way | 1P16S | 2P16S | 3P16S | 4P16S | 5P16S |
Battery module capacity | 5.12KWh | 10.24KWh | 15.36KWh | 20.48KWh | 25.6KWh |
Rated Capacity | 100Ah | ||||
Rated voltage | 51.2V | ||||
Charging temperature | 0~55ºC | ||||
Discharge temperature | -10~55ºC | ||||
Storage temperature | -20~45°C (≤1 month);0~35°C (>1 month) | ||||
Working humidity | 5~95%(no condensation) | ||||
Maximum altitude | <3000m(>2000m derating) | ||||
Protection degree | IP54 | ||||
Cell charging cut-off voltage | 3.6V | ||||
Single discharge cut-off voltage | 2.8V | ||||
Working voltage range | 44.8V~57.6 | ||||
Communication method | CAN, RS485 | ||||
Parallel communication | 6pcsinMax | ||||
BMS power consumption | <2W(underworkingcondition,) sleep< 50mW(inhibernatemode) | ||||
Rated operating current | 50A | 100A | 100A | 100A | 100A |
Maximum perating current | 100A | 110A | 110A | 110A | 110A |
Cycle performance | ≥6000 times, 25°C | ||||
Certification standards | UL9540A,IEC62619/IEC642277,EMC ,UN38.3 ,UL1973 | ||||
Service life | 10year | ||||
Size(L*W*H) | 600*850*363mm | 600*850*363mm | 600*850*726mm | 600*850*726mm | 600*850*1100mm |
Installation | Indoor/Outdoor | ||||
Weight | 51kg | 82kg | 133kg | 164kg | 195kg |
Protection function | Overvoltage/overvoltage/overcurrent/short circuit/reverse connection |
Suppliers with verified business licenses