20 AMP Breaker Afdd Fuse Box DC Arc Fault Detection Device

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Air
Installation: Fixed
Structure: Afdd
Samples:
US$ 85/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Description
  • Company Profile
Overview

Basic Info.

Model NO.
GDDF
Poles Number
2
Type
Circuit Breaker
Function
Arc Fault Circuit Interrupter
Certification
CB
Frequency
50Hz
Rated Voltage
230V
Transport Package
Standard
Specification
32A
Trademark
GEYA
Origin
Zhe

Product Description

Product Description
GDDF-63 Arc fault protective MCB+RCD
GDDF-32 Arc fault circuit breaker
GDDF3-40 Arc fault protective RCBO
GDDF2N-32 Arc fault circuit breaker 1P+N
GDDF2-32 Arc fault circuit breaker 1P+N
GDDF2L-32 Arc fault protective RCBO
GDDA-40 Arc fault detector

Overview:
AFDD-32 incorporating MCB and arc fault detection module, provides protection against short circuit, overload, and arc fault. The incorporated arc fault module detects and identifies arc fault, which enables the product effectively disconnect the protected circuit against arc fault
Application:
AFDD-32, applicable to AC circuits with rated current up to 32A, is widely used for household and similar installations.
The arc fault detection module of AFDD-32 can effectively detect and identify arc faults that happened to different circuits connected in series, in parallel, and to earth resulting from disabled insulation layers due to aging, damaging, or high humidity. The product trips and disconnects a protected circuit upon detection of arc faults.
Main technical parameters:
1)Rated voltage(Ue): AC230V 
2)Rated frequency:50HZ±2%
3)Rated insulation voltage(Ui): 400V 
4)Rated impulse withstand voltage(Uimp):4KV
5)Rated current(In):6A,10A,16A,20A,25A,32A 
6)Magnetic tripping type: B-type,C-type 
7)Rated service short circuit capacity(Ics):6KA 
8)Rated short circuit capacity(Icn): 6KA 
9)Insulation material class: III a 
10)Grid distance(mm):40mm
Classification:
Classified by rated current: 6A, 10A,16A,201,25A,32A 
Classified by magnetic tripping type: B and C type
Normal operating conditions:
The ambient temperature is 5ºC or+40ºC, the average daily highest temperature is+35ºC. 
Relative humidity: Maximum value is 50% when the temperature is 40ºC and 90% when the temperature is 20ºC.

20 AMP Breaker Afdd Fuse Box DC Arc Fault Detection Device20 AMP Breaker Afdd Fuse Box DC Arc Fault Detection Device

Company Profile

20 AMP Breaker Afdd Fuse Box DC Arc Fault Detection Device20 AMP Breaker Afdd Fuse Box DC Arc Fault Detection Device20 AMP Breaker Afdd Fuse Box DC Arc Fault Detection Device20 AMP Breaker Afdd Fuse Box DC Arc Fault Detection Device20 AMP Breaker Afdd Fuse Box DC Arc Fault Detection Device

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory
Number of Employees
106
Year of Establishment
2007-02-28