Theory: Time Relay
Usage: Multifunctional Time Relay
Phase: 1
Samples:
US$ 25/Piece 1 Piece(Min.Order)
| Order Sample
Discussion
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Geya Grt8-Rl-230 AC230V 10 Time Ranges Right-Left Inverser Time Relay for 2 Different Loads pictures & photos
Geya Grt8-Rl-230 AC230V 10 Time Ranges Right-Left Inverser Time Relay for 2 Different Loads
US $9.42-11.59 / Piece
Min. Order: 50 Pieces
Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Product Description
  • Certifications
  • Packaging & Shipping
  • Company Profile
Overview

Basic Info.

Model NO.
GRT8-RL-230
Electricity Type
AC/DC
Number of Pole
2
Load
Low Voltage
Protective Characteristics
Sealed Relay
Action Principle
Electronic Type
Size
Miniature
Type
Electric Parameter Relay
MOQ
50
Transport Package
Standard Box
Specification
AC230V
Trademark
GEYA
Origin
Zhe

Packaging & Delivery

Package Size
5.00cm * 10.00cm * 15.00cm
Package Gross Weight
0.250kg

Product Description

Product Description

Applications
 -Right-Left(inverser) timer relay is used for 2 different loads, which works by turn. The first load starts working, stops and waits(off ), and the second load starts working. Both working times are the same.

Function Features
-The default is right load first. You can select left load first by shorting S-A1
 -Time scale 0.1 s - 100 days divided into 10-time ranges:
 (0.1 s - 1 s / 1 s - 10 s / 0.1 min - 1 min / 1 min - 10 min / 0.1 hrs - 1 h / 1 hrs - 10 hrs / 0.1 day - 1 day /1 day - 10 days /3 days - 30 days / 10 days - 100 days).
 -Relay status is indicated by LED.
 -1-MODULE, DIN rail mounting.

 

  GRT8-RL
Function Right-left inverser time relay
Supply terminals A1-A2
Voltage range(W240) AC/DC 12-24V(50-60Hz)
Burden(W240) AC 0.7-3VA/DC 0.5-1.7W
Voltage range(A230) AC230V(50-60Hz)
Power input(A230) AC max.6VA/1.3W         AC max.6VA/1.9W
Supply voltage tolerance -15%;+10%
Supply indication green LED
Time ranges 0.1s-10day
Time setting potentiometer
Time deviation 5%-mechanical setting
Repeat accuracy 0.2%-set value stability
Temperature coefficient 0.05%/ºC,at=20ºC(0.05%°F, at=68°F)
output 2×SPDT
Current rating 16A(AC1)
Switching voltage 250VAC/24VDC
Min.breaking capacity DC 500mw
Output indication red LED
Mechanical life 1×10^7
Electrical life(AC1) 1×10^5
Resettime max.200ms
perating temperature -20ºC to+55ºC(-4°F to 131°F)
Storage temperature -35ºCto+75ºC (-22°F to 158°F)
Mounting/DIN rail Din rail EN/IEC 60715
Protection degree IP40 for front panel/IP20 terminals
Operating position any
overvoltage cathegory III.
Pollution degree 2
Max.cable size(mm²) solid wire max.1×2.5 or 2×1.5/with sleeve max.1×2.5(AWG12)
Dimensions 90×18×64mm
Weight W240-82g,A230-82g
Standards EN61812-1,EN61010-1
Certifications

Geya Grt8-Rl-230 AC230V 10 Time Ranges Right-Left Inverser Time Relay for 2 Different Loads

Packaging & Shipping

Geya Grt8-Rl-230 AC230V 10 Time Ranges Right-Left Inverser Time Relay for 2 Different Loads

Company Profile

 

Geya Grt8-Rl-230 AC230V 10 Time Ranges Right-Left Inverser Time Relay for 2 Different Loads
Geya Grt8-Rl-230 AC230V 10 Time Ranges Right-Left Inverser Time Relay for 2 Different Loads
Geya Grt8-Rl-230 AC230V 10 Time Ranges Right-Left Inverser Time Relay for 2 Different Loads

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Geya Grt8-Rl-230 AC230V 10 Time Ranges Right-Left Inverser Time Relay for 2 Different Loads pictures & photos
Geya Grt8-Rl-230 AC230V 10 Time Ranges Right-Left Inverser Time Relay for 2 Different Loads
US $9.42-11.59 / Piece
Min. Order: 50 Pieces
Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Number of Employees
106
Year of Establishment
2007-02-28