·········This link price is only for GRV8-03X M265········
Product Description
Applications
-Control for connection of moving equipment(site equipment,
agricultural equipent,refrigerated trucks).
-Control for protection of persons and equipment against the consequences of reverse running.
-Normal/emergency power supply switching.
-Protection against the risk of a driving load(phase failure).
Function Features
-Controls its own supply voltage(True RMS measurement).
-Set 8-level rated operating voltage through knob.
- Measuring frequency range:45Hz-65Hz.
- Voltage measurement accuracy<1%.
- Anti-harmonic design, optimized for high interference
occasions.
- Relay status is indicated by LED.
- 1-MODULE,DIN rail mounting.
![Geya Grv8-03X M265 Three Phase Voltage Monitoring Relay Adjustable Delay Time 220V](//www.micstatic.com/athena/img/transparent.png)
![Geya Grv8-03X M265 Three Phase Voltage Monitoring Relay Adjustable Delay Time 220V](//www.micstatic.com/athena/img/transparent.png)
![Geya Grv8-03X M265 Three Phase Voltage Monitoring Relay Adjustable Delay Time 220V](//www.micstatic.com/athena/img/transparent.png)
![Geya Grv8-03X M265 Three Phase Voltage Monitoring Relay Adjustable Delay Time 220V](//www.micstatic.com/athena/img/transparent.png)
![Geya Grv8-03X M265 Three Phase Voltage Monitoring Relay Adjustable Delay Time 220V](//www.micstatic.com/athena/img/transparent.png)
![Geya Grv8-03X M265 Three Phase Voltage Monitoring Relay Adjustable Delay Time 220V](//www.micstatic.com/athena/img/transparent.png)
Product Parameters
Technical parameters |
M460 |
M265 |
Function |
Monitoring 3-phase voltage |
Monitoring terminials |
L1-L2-L3 |
L1-L2-L3-N |
Supply terminals |
L1-L2 |
L1-N |
Voltage range |
220-230-240-380-400
-415-440-460(P-P) |
127-132-138-220-230-240-254-265(P-N) |
Rated supply frequency |
45Hz-65Hz |
Measuring range |
176V-552V |
101V-318V |
Threshold adjustment voltage |
2%-20% of Un selected |
Adjustment of asymmetry threshold |
5%-15% |
Hysteresis |
2% |
Phase failure value |
70%of Un selected
Min=165V |
70%of Un selected |
Time delay |
Adjustable 0.1s-10s,10% |
Measurement error |
≤1% |
Run up delay at power up |
0.5s time delay |
Konb setting accuracy |
10% of scale value |
Supply indication |
green LED |
Output indication |
red LED |
Reset time |
1000ms |
Output |
1×SPDT |
Current rating |
10A/AC1 |
Switching voltage |
250VAC/24VDC |
Min.breaking capacity DC |
500mW |
Temperature coefficient |
0.05%/ºC,at=20ºC(0.05%F,at=68F) |
Mechanical life |
1*10^7 |
Electrical life(AC1) |
1*10^5 |
Operating temperature |
-20ºC to +55ºC(-4ºF to 131ºF) |
Storage temperature |
-35ºC to +75ºC(-22ºF to 158ºF) |
Mounting/DIN rail |
Din rail EN/IEC 60715 |
Protection degree |
IP40 for front panel/IP20 terminals |
Operating position |
any |
Overvoltage category |
III |
Pollution degree |
2 |
Tightening torque |
0.8Nm |
Max.cable size(mm^2) |
solid wire max.1×2.5or 2×1.5/withsleeve max.1×2.5(AWG12) |
Dimensions |
90×18×64mm |
Weight |
61g-66g |
Certifications
![Geya Grv8-03X M265 Three Phase Voltage Monitoring Relay Adjustable Delay Time 220V](//www.micstatic.com/athena/img/transparent.png)
Packaging & Shipping
![Geya Grv8-03X M265 Three Phase Voltage Monitoring Relay Adjustable Delay Time 220V](//www.micstatic.com/athena/img/transparent.png)
Company Profile
![Geya Grv8-03X M265 Three Phase Voltage Monitoring Relay Adjustable Delay Time 220V](//www.micstatic.com/athena/img/transparent.png)
![Geya Grv8-03X M265 Three Phase Voltage Monitoring Relay Adjustable Delay Time 220V](//www.micstatic.com/athena/img/transparent.png)