Customization: | Available |
---|---|
Theory: | Time Relay |
Usage: | on/off Delay Time Relay |
Still deciding? Get samples of US$ 20/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
GRT8-X1 | GRT8-X2 | |
Function | 20 functions | |
Supply terminals | A1-A2 | |
Voltage range(W240) | AC/DC 12-24V(50-60Hz) | |
Burden(W240) | AC 0.09-3VA/DC 0.05-1.7W | |
Voltage range(A230) | AC230V(50-60Hz) | |
Power input(A230) | AC max.6VA/1.3W | AC max.6VA/1.9W |
Supply voltage tolerance | -15%;+10% | |
Supply indication | green LED | |
Time ranges | 0.1s-99day,ON,OFF | |
Time setting | Key setting | |
Time deviation | ≤1% | |
Repeat accuracy | 0.2%-set value stability | |
Temperature coefficient | 0.05%/ºC,at=20ºC(0.05%°F, at=68°F) | |
output | 1×SPDT | 2×SPDT |
Current rating | 16A(AC1) | 2x16A(AC1) |
Switching voltage | 250VAC/24VDC | |
Min.breaking capacity DC | 500mw | |
Output indication | red LED | |
Mechanical life | 1×10^7 | |
Electrical life(AC1) | 1×10^5 | |
Resettime | max.200ms | |
perating temperature | -20ºC to+55ºC(-4°F to 131°F) | |
Storage temperature | -35ºCto+75ºC (-22°F to 158°F) | |
Mounting/DIN rail | Din rail EN/IEC 60715 | |
Protection degree | IP40 for front panel/IP20 terminals | |
Operating position | any | |
overvoltage cathegory | III | |
Pollution degree | 2 | |
Max.cable size(mm²) | solid wire max.1×2.5 or 2×1.5/with sleeve max.1×2.5(AWG12) | |
Dimensions | 90×18×64mm | |
Weight | 1xSPDT:W240-62g,A230-60g | |
2xSPDT:W240-82g,A230-81g | ||
Standards | EN61812-1,IEC60947-5-1 |