··········This link price is only for GYAR9-AC-G AC~220V···········
Product Description
Product Features
1.Visual voltage display makes it easier formaintenance personnel to judge the circuitduring maintenance.
2.Equipped with a LOCK padlock device toachieve a double protection mechanismand provide additional protection forcircuit maintenance
3.Supports MODBUS 485 remote communication function to remotely understand the working status of thedevice
4.Supports local operation fault storage,and when the remote communicationfunction is restored,the device data canbe read
5.Remote automatic mode can operate safely and efficiently based on MCU self-test
Product Parameters
Standard |
EN 50155,GB/T 24338.4-2018,EN 45545-2,IEC 61373 |
Adaption |
Acti9 Series 1P-4 |
Electrical Characteristics |
|
Operating Voltage |
230V AC(70%~125%)24-48V DC(optional) |
Control signal |
MODBUS-RS485 Wet node 230V high level/pulse signal (optional) |
Over&Under voltage function |
160-275V±5V(optional) |
Timing function |
Available(optional) |
Digital display |
3-digit voltage,switching times,fault status |
Effective control signal duration |
>400ms |
Closing action time |
<1s |
Opening action time |
<0.5s |
Control circuit cable length |
≤1500m |
Current-carrying capacity of auxiliary contacts(terminals 8-9-10) |
1CO,minimum operating current 3mA(24VDC)(resistive)(optional) |
Current-carrying capacity of signaling contacts(terminals 5-6-7) |
Maximum operating current 2A(30V DC),0.5A(125V AC)(optional) |
Power consumption |
≤1.5VA(static);≤25VA(dynamic) |
Rated insulation voltage |
400V |
Rated Impulse Withstand Voltage Uimp (between S2C-RM DC and MCB |
4kV(4.9KV at sea level) |
Self-locking protection |
Within 10s of 3CO/20s of 4CO/30s of 6CO,the product will self-lock and recover automatically after 40s. |
Electrical life |
10000 times,3 times/minute |
Mechanical Characteristics |
|
Indicator Light |
Green,Normal status |
Auto/Manual switching |
Auto Remote control of opening&closing available Manual Remote control of opening&closing disabled |
Mechanical life |
10000 |
Protection class |
lp20 |
Hazard class according to EN 45545-2 |
EN 45545-2 R26/HL3 |
Shock and vibration resistance According to IEC 61373 |
category 1-class A/B-body mounted |
Resistance to heat and humidity IEC/EN 60068-2-30 |
28 cycles(55ºC/90-96%,25ºC/95-100%) |
Ambient Temperature |
-25…+70ºC |
Storage Temperature |
-40...+70ºC |
Installation and Wiring |
|
Power and control signal terminal wiring capacity |
28-12AWG 2.5mm² |
Auxiliary signal terminal wiring capacity |
28-14AWG 1.5mm² |
DIN rail mounting |
DIN rail EN 60715(35 mm) |
Mounting position |
Mounting on DIN rail Any position |
Certifications
Packaging & Shipping
Company Profile